● The Advantest Q8347 is an optical spectrum analyzer employing aMichelsoninterferometer
● High resolution wavelength measurement of0.01nmat1.5μmband and0.001nmat0.5μmband
 
● Coherent length can be measured
 The coherent length, which cannot be measured by dispersion spectroscopy using a grading based spectrum analyzer, can be measured by Q8347 using the Michelson interference method.  Therefore, the Q8347 can easily determine the noise suppression performance of the CD/VD laser diode due to the reflected light. The analysis range is as wide as +/-165mm.
 
● High-speed measurement
As the analyzer employs Fourier spectroscopy using Michelson interferometer, high speed measurement is realized.
 
● +/-0.01nm wavelength measurement accuracy
As a He-Ne laser is used as internal reference light source, a high wavelength accuracy of 0.01nm is realized. Wavelength calibration is not required.
 
● Easy operation
Various aspects have been taken into consideration to make measurement easier. The panel key arrangement, Soft-key menus and basic key function can be specified in the first hierarchy.  The Q8347 has a built-in level meter which greatly facilitates adjustment of the measurement light coupling.
 
● Zoom function
The measurement data can be analyzed again and displayed with the zoom function.  Data can be displayed from wide to narrow span without repeating measurement.
 
● Various processing functions
They include four types of FWHM measurement function, an automatic peak search function, four types of cursor indication modes, a peak value sting function and 16 data memory areas.
 
● Built-in high-speed printer
 Measurement data can be easily output using a high-speed thermal printer having a printing speed of less than 8 seconds.
 
Specification
  
Wavelength         350nm - 1750 nm  
  
Resolution          0.001nm / 500nm (high resolution mode)
                           0.003nm / 850nm (high resolution mode) 
                           0.01nm / 1550nm (high resolution mode)
                                   0.05 nm / 850nm (normal resolution mode)
                                   0.1 nm / 1550nm (normal resolution mode)
 
Wavelength Accuracy   ±0.01 nm or less(high resolution mode)
                                       ±0.1 nm or less (normal resolution mode)
 
Span                 0.01nm /DIV to 140nm/DIV
 
Input Sensitivity   -72 dBm to +10 dBm  (1.2μm to 1.6 μm)
                                      -65 dBm to +10 dBm  (0.7μm to 1.6 μm)
                                      -52 dBm to +10 dBm  (0.45μm to 1.7 μm)
                                      -42 dBm to +10 dBm  (0.35μm to 1.7 μm)
 
Level accuracy       ±1.0dB (780nm), ± 0.7dB (1310,1550 nm)
 
Dynamic range      35dB or more
 
Repeatability including polarization dependence±0.1dB or less at 1550nm
 
Level scale               0.2,  0.5,  1.0,  2.0,  5.0,  10.0 dB/DIV and linear
 
Measurement time        1 second or less
 
Memory function     16screens ( measurement data) with battery backup
                                           10 screens (measurement condition) with battery backup
                                           Floppy disk (MS-DOS format: 720KB / 1.2 MB)
 
Display            Frequency, superimpose, 3-dimensional trend monitor (power,
                               Wavelength), dual screen (up/down) display, cursor function,
                               Color display customization, Listing
 
Calculation Analysis ●Spectrum analysis ●Coherence analysis ●Spectral half-width
                                             Calculation ●Averaging ●Automatic optimum measurement
                                             ●Smoothing ●Automatic peak search ●Normalizing ● Curve
                                             Fit ● MAX/MIN hold
 
Optical Input connector   FC connector
 
Data Output     ●GPIB Standard equipment ● direct plotter ● Built-in printer\
 
External Dimensions  Main unit:  424(W) X 221(H) X 500(D)  mm
                                              Optical unit: 424 (W) X 132(H) X 500(D) mm
 
Mass                   Main unit: about 16 Kg
                                   Optical unit about 20 Kg

Online Purchasing

  • *
  • *
  • *
  • *
  • * Can't see clearly? Click on the Change Picture
Recommendation information

Recommended products

Agilent 81577A
Agilent 81577A
Lightwave LDC-3724B
Lightwave LDC-3724B
newport 8016
newport 8016
newport 8008
newport 8008
MP1800A
MP1800A
  • Rich experience

    Rich experience

    Several senior instrument maintenance engineers

  • Advanced technology

    Advanced technology

    The company has advanced technology.

  • Excellent quality

    Excellent quality

    Provide quality assurance for customers

  • Perfect after sale

    Perfect after sale

    To provide customers with perfect after-sales service.

CopyRight © 2020 zcyxiu.com All Rights Reserved. Shenzhen Zhongce Yixiu Optoelectronic Technology Co., Ltd.

网站ICP备案号:
Support:Website | zk71  | Manage
  • This site supports multi-terminal browsingThis site supports multi-terminal browsing